Automotive Cables

  
Germany Standard

Japanese Standard

American Standard

 

 

Material Properties
Insulation & Sheath Material Properties Related To Automotive of Cable

Insulation and Sheath Materials

 

abbreviation

 

 

Insulation Material

Chemical description

 

 

Shart symbol

Acc. To DIN 76722 

 

Classification

Acc.to

ISO 6722 

 

Continuous

Duty

Temperature

(3.000h)℃ 

 

Thermal overload capacity

℃/48h 

 

Cold bending

Resistance

 

PVC

Polyvinyl Chloride

Y(YW)

 

A/B

 

90/105

140

 

-40

 

PA(Lenio家的)

Polyamide

4Y

-

105

140

-50

XLPE

Polyethylene,cross-linked

12X

 

125

150

-40

TPE-E

 

Thermoplastic

Polyester elastomer

13Y

 

 

C

 

100

 

150

 

-40

 

TPE-U

(PUR)

 

Themoplastic polyether polyurethane

11Y

 

 

C

 

125

 

150

 

-50

 

PVC-P

Hot-pressure resistant, heat-resistant

YW

 

125

140

-40

EVA

 

Ethylene-vinyl acetate

4G

 

C

 

130

 

160

 

-40

 

ETFE

Ethylen tetrafluoroethylene

7Y

E

180

230

-65

FEP

Tetrafluoroethylene hexafluoropropylene

6Y

F

210

240

-65


Specific resistance

At 20℃

 

Ω×cm

Shore hardness

A/D

Tensile strength

 

M Pa

Elongation at break

 

%

Abrasion

Flame

Retardant

Resistant against:

Oil

Fuel

Breaking

Fluid

Acid/Lye

Organic

media

>1012

A85-95

>10

>150

+

+

+

+

-

+

-

>1012

D72

>40

>300

++

-

++

++

+

+

+

>1014

95A

>10

>200

+

+

+

+

-

+

+

>1010

D40-78

>25

>300

++

-

++

++

+

-

+

>109

A75-D54

>30

>300

++

-

++

++

+

+

+

>1012

92A-97A

>15

>150

+

+

+

+

-

+

-

>1013

A80-90

>10

>200

+

-

+

+

+

+

+

>1016

D75-80

>30

>150

++

+(+)

++

++

++

++

++

>1016

D55-60

>15

>200

++

++

++

++

++

++

++


Resistant against

Oil

Fuel

Breaking Fluid

Acid/Lye

Organic media

+

+

-

+

-

++

++

+

+

+

+

+

-

+

+

++

++

+

-

+

++
++
+
+
+
+
+
-
+
-
+
+
+
+
+
++
++
++
++
++
++
++
++
++
++